    10kVA UPS Backup Uninterruptible Power Supply

    $3,565.87
    Uninterruptible Power Supply, 10kVA/8kW, line interactive UPS, easy operation, provide a reliable battery backup and safeguard the power for critical devices against power surges and outages.
    SKU: ATO-BE-10K
    *
    *
    *
    *
    Free shipping
    Delivery date: 6-12 days

    Applications

    10kVA/8000 Watts UPS is an uninterruptible power supply to provide emergency power to a load, and it is mainly used in computer, office equipment, test equipment, light system, safe alarm system, ray equipment, medical equipment, copymachine, numerical control machine tools, industrial automation equipment, color and drying equipment, Hi-Fi equipment etc.

    8000W UPS Specification

    Basic Model ATO-BE-10K
    Rated Capacity 8000W/10kVA
    Weight 80kg
    Size 540*270*590mm
    Input Input Voltage Range 160-275V AC
    Nominal Input Voltage 220/230/240/110/120V AC
    Input Frequency 45-65Hz
    Output Norminal Output Voltage 220/230/240/110/120V AC
    Output Voltage Range (Normal Mode) 220/230/240/110/120V AC±10%
    Output Voltage Range (Battery Mode) 220/230/240/110/120V AC±10% (Modified Sine Wave)
    Output Frequency (Normal Mode) Synchronized (Sine Wave)
    Output Frequency (Battery Mode) 50/60Hz±0.2%
    Wave Form Modified Sine Wave
    Power Factor 0.9
    Efficiency >90%
    Transfer Time 6-8ms
    Batteries & Runtime Battery Type Maintenance-free lead-acid battery
    Battery Modules 12v*7Ah*8pcs
    Backup Time (full/half load) 5 Minutes Backup time; for long backup mode, it depends on outside battery
    Charge Time <12 hours (90%)
    Display Status LCD (NORMAL, FAULT, BATTERY, CHARGE, OVERLOAD)
    Protection Overload Protection Automatic shut down when overload is within 110~130%
    Shut down after 300ms when above 130%
    Others Peak Ratio for Load 3:1 (Max.)
    Distortion Rate (full load) Linear Load <3%
    Distortion Rate (full load) Non-linear Load <6%
    Communication Software NETCCA POWER
    Operating Environment Working Temperature 0°C~40°C
    Relative Humidity 20~90% Non-condensing

    UPS Input Power Cables (Optional)

    UPS input power cables

    UPS Output Sockets (Optional)

    UPS output sockets

    Tips: The battery voltage is low but the battery cannot be charged for more than 10 hours.

    Judging from the phenomenon it is the fault of battery and charging circuit, which can be inspected according to the following procedures.

    1. Check whether the input and output voltage of the charging circuit is normal. 
    2. If the charging circuit is in normal input and abnormal output, disconnect the battery to test again. If it is still abnormal, it is the fault of the charging circuit.
    3. If the charging circuit has normal input and output after the battery is disconnected, it indicates that the battery has been damaged because of the long term charging, long time placement, due life period.