Close
(0) Shopping cart
You have no items in your shopping cart.
Shopping Categories
    Filters
    Preferences
    Search

    7 hp (5.5 kW) 3 Phase AC Input Line Reactor for VFD

    $76.50
    The inexpensive 3.7 kW AC input line reactor for VFD, 3 phase, 15A rated current, with 380V, 400V, 440V, 460V, 480V and many other voltages, not only affordable but also high quality, brand new direct sale by factory.
    SKU: ATOACR-0015-0M94-0.4SC
    *
    *
    Free shipping
    Delivery date: 6-12 days

    7 hp Input Line Reactor Features

    3.7 kW AC input line reactor,3 phase for VFD. It is a light weight, high performance and long life line reactor with 15A. The perfect reactor has a variety of voltage options, such as 220V, 380V, 400V, 460V and 480V, etc. It is widely used in various power supply places with a frequency of 50Hz/60 Hz and is worth your choice.

    7 hp Input Line Reactor Specifications

    Basic Model ATOACR-0015-0M94-0.4SC
    Phase 3 Phase
    Power 7 hp (5.5 kW)
    Weight 3 kg
    Technical Parameters Work Valtage 380V (optional: 220V/ 240V/ 400V/ 415V/ 440V/ 460V/ 480V)
    Work Frequency 50Hz/60 Hz
    Rated Current 15 A
    Max Current 1.5 Times the Rated Current, Continued 60s
    Inductance Value 0.94 mH
    Material Aluminium/Copper (Optional)
    Voltage Drop 2%
    Noise ≤65dB
    Insulation Class Class F, H
    Protection Class IP00-IP22
    Insulation Resistor ≥100MΩ
    Working Environment Operation Environment -10℃~+45℃
    Temperature Rise ≤85K
    Humidity ≤90%RH, without condensation
    Running Ambient Temperature -25℃~+45℃
    Altittude ≤2000m

    7 hp Input Line Reactor Size & circuit diagram

    ac reactor sizecircuit diagram

    Dimension (±5mm)
    L D W W1 H A×B
    115mm 90mm 95mm 68mm 135mm 6×11

    Tips:

    Reactors have a variety of functions to improve the reactive power, including:

    • Capacitance effect on light airborne or lightly loaded lines to reduce power frequency transient overvoltage.
    • Improve the voltage distribution on long-distance transmission lines.
    • Make the reactive power in the line as light as possible on the light load, prevent the irrational flow of reactive power and reduce the power loss on the line.
    • When the large unit is in parallel with the system, reduce the steady-state voltage of the power frequency on the high-voltage bus, so that the generators can be juxtaposed at the same time.
    • Prevent self-excitation resonance phenomenon that may occur in the long line of the generator.
    • When the neutral point of the reactor is used to pass the small reactance grounding device, the small reactor can also be used to compensate the phase and phase capacitance of the line to accelerate the automatic extinguishing of the submerged current, which is convenient to adopt.