265 amp 3 phase AC Magnetic Contactor, 24V/110V/220V Coil

$466.63
ATO 3 pole 3 phase AC magnetic contactor with rated current up to 265A, 24V/110V/220V coils, is suitable for switching and controlling electric motors for industrial applications. This AC contactor relay has a wide selection of contact form to choose from.
*
*
SKU: ATO-ACCON-265A
30-day Returns
Free Shipping
Delivery date: 6-12 days

3 pole AC magnetic contactor is used in 3 phase units. This contactor relay works between power source and high load electrical motor to balance changes in electrical frequency which may come from a power supply.

Specification

Model ATO-CJX2-F265
Rated Current le max AC-3 (Ue≤440V) 265A
le max AC-1 (θ≤40°C) 350A
Coil Rated Voltage (Optional) 110V AC, 220V AC, 380V AC
Contact Form 3NO
Auxiliary Contact (Optional) 2NO, 2NC, 1NO+1NC, 2NO+2NC, 1NC+3NO, 4NO, 4NC
Frequency 50Hz/ 60Hz
Rated Insulated Voltage (Ui) 1000V
Rated Impulse Withstand Voltage (Uimp) 8kV
Rated Operational Voltage 440V
Conventional Thermal Current (θ≤40°C) 350A
Operation Frequency AC-1, AC-2, AC-3 1200 times/h
AC-4 300A
Rated Power (AC-3) 220/240V 75kW
380/400V 132kW
415V 140kW
440V 140kW
500V 160kW
660/690V 160kW
1000V 147kW
Connection/ Wiring Number of Lines 2
Line Size 32x4mm2
Cable with Splicing 240mm2
Cable with Connector 240mm2
Screw Diameter φ10
Tightening Torque 35N.m
Standards-Compliant IEC60947-4-1, GB14048.4, EN60947-4-1
Dimensions 203 x 201.5 x 213mm
Weight 16kg

Details

265 amp 3 phase AC Magnetic Contactor Details

Tips: Three attributes of AC magnetic contactor

  • AC magnetic contactor coil. Coils are usually identified by A1 and A2, which can be simply divided into AC contactors and DC contactors.
  • Main contact of AC contactor. L1-L2-L3 is connected to the three-phase power supply line, and T1–T2-T3 is connected to the power supply line, which can be used to connect the load line. The main contacts of AC contactors are normally open contacts, which are mainly connected to the main circuit to control the start and stop of motors and other equipment.
  • Auxiliary contact of AC contactor. Auxiliary contacts can be divided into normally open point NO and normally closed point NC. In general, the normally open point NO is mainly used for contactor self-locking control and transmission of operating signals. For example, AC contactor normally open point NO connected to a red indicator light can be used as the electrical motor’s running indicator light. When power is on, the normally open point NO is closed and the indicator light is turned on to transmit the operating signal of the motor or circuit. The normally closed point NC of the AC contactor is mainly used for circuit interlocking and signal transmission.