4-20mA Signal Isolator, 0-20mA/0-5V/1-5V/0-10V/2-10V

5 out of 5 based on 1 reviews | Write a review
$96.88
4-20mA signal isolator for sale. It is equipped with the fastest response time of <2ms, accuracy 0.1%FS (20℃), and 35mm DIN Rail Installation. Output signal 4~20mA/0~20mA/1~5V/0~10V/2~10V is optional. High performance analog signal isolator is suitable for signal isolation/conversion/distribution of Sensors, DCS systems, electrical cabinets, PLC cabinets, and paperless recorders.
*
*
*
SKU: ATO-SIGNI-1002S
30-day Returns
Free Shipping
Delivery date: 6-12 days

4-20mA signal isolator provides the fastest response time <2ms, accuracy 0.1%FS (20℃), and 35mm DIN Rail Installation, and optional input/output signal 4~20mA/0~20mA/1~5V/0~10V/2~10V. This analog signal isolator can be used for pressure transmitters, electromagnetic flow meters, current transmitters, temperature transmitters, etc.

Specifications

  • Model: ATO-SIN-1002S
  • Input Signal: 4~20mA, 0~20mA
  • Input Resistance: Current Impedance≤100Ω
  • Input Current: ≤30mA
  • Distribution Voltage: ≥20V@20mA
  • Output Signal: 0~20mA, 4~20mA, 1~5V, 0~10V, 2~10V
  • Output Load: 4~20mA, 0~20mA, Load Resistance RL≤550Ω; 0~5V, 1~5V, 0~10V, 2~10V, Load Resistance RL≥1MΩ
  • Power Supply: DC 20~35V
  • Power Consumption: Single Output Power Consumption: ≤1.5W; Dual Output Power Consumption: ≤2.6W
  • Dielectric Strength: 1500V AC
  • Operating Temperature: -20~60℃
  • Relative Humidity: 25%~85%
  • Storage Temperature: -20~60℃
  • Temperature Drift: ≤50ppm
  • Installation Method: 35mm DIN Rail Installation
  • Transmission Accuracy: 0.1%FS (20℃)
  • Response Time: ≤2ms
  • Compatibility: Comply with GB/T18268 Industrial Equipment Application Requirements (IEC 61326-1)
  • Applicable Equipment: Two-wire and Three-wire Transmitters, DC Current Sources

Dimensions (Unit: mm)

0-10V signal isolator dimension

Installation

0-10V signal isolator installation

Wiring

4-20ma signal isolator wiring

Applications

ATO analog signal isolators are commonly used in industrial automation, process control, power distribution, and any application where electronic signals need to be transmitted between components that operate at different electrical potentials.

0-10V signal isolator applications

Tips: What is an analog signal isolator?

An analog signal isolator is a device designed to electrically separate and protect analog signals transmitted between two components or systems. The primary purpose of an analog signal isolator is to prevent unwanted electrical interactions, such as ground loops and interference, that can affect the accuracy and reliability of analog signals.

Analog signal isolators typically work by using techniques such as transformers or optocouplers to create an electrical barrier between the input and output sides. The input signal is converted into an isolated signal, allowing it to be transmitted to the output side without a direct electrical connection. This isolation helps in applications where different parts of a system operate at different potentials or where there's a need to protect sensitive equipment from potential damage caused by electrical disturbances.

Analog signal isolators are commonly used in industrial automation, process control, and other applications where precise and interference-free transmission of analog signals is critical.

Existing reviews of 4-20mA Signal Isolator, 0-20mA/0-5V/1-5V/0-10V/2-10V
Effective signal isolator
After using this 4-20mA signal isolator, data transmission has become more stable and accurate. The installation is very simple, the standard rail mounting design is very considerate, and the wiring method is clear and easy to understand. It has a fast response speed, almost no delay, and the isolation effect is obvious.
From: Arabella | Date: 11/05/2025
Was this review helpful? Yes No (0/0)
Write your review for 4-20mA Signal Isolator, 0-20mA/0-5V/1-5V/0-10V/2-10V
  • Only registered users can write reviews
  • Bad
  • Excellent
Customers who bought this item also bought

Submersible Level Sensor for Water/Oil/Fuel Tank, 0-200M

$173.28
SKU: ATO-LEVS-S200M
Submersible level sensor adopts 304 stainless steel housing and waterproof cable, can be put in water/oil/fuel tank or reservoir directly for liquid level measurement. The measuring range can be 0-1m/0-3m/0-5m/0-10m ~ 0-200m. Liquid level sensor has optional accuracy 0.5%FS or 0.3%FS, output signal 4-20mA/0-5V/RS485, power supply DC 24V/12V. The cable type and connection type are also customizable.

4-20mA/0-5V/0-10V to RS485 Converter, 2 Channel

$72.53
SKU: ATO-TR-2-Channel
The 4-20mA to RS485 converter module can collect up to 2 channels of analog signals (4-20mA, 0-10V, 0-5V) and upload them to 485 interface standard ModBus-RTU communication protocol. 485 interface up to 2000 meters, can be directly accessed to the site of the PLC, industrial control instrumentation, configuration screen or configuration software.

4-20mA PWM Signal Generator

$130.01
SKU: ATO-SG-003A
Digital 4-20mA signal generator is equipped with a large-capacity 3000mAh lithium battery, Type-C interface (5V), adjustable button backlight high-definition TFT color LCD screen and multiple signal generator functions. This multifunction PWM signal generator is mainly used for debugging industrial field PLC, process instrumentation, and electric valves.

Ultrasonic Level Sensor for Tanks, Output 4-20mA/1-5V/RS485, 0-40M

$475.98
SKU: ATO-LEVS-U40M
Ultrasonic level sensor has high accuracy 0.3%FS and measuring range 0-5m, 0-10m, 0-15m to 0-40m. It also adopts integrated structure and mainly consists of OLED display, waterproof connectors and ultrasonic probe. Ultrasonic tank level sensor using advanced non-contact ultrasonic measurement technology can be used for liquid/solid/powder level of tapered/spherical tank, tapered feed outlet tank, sewage tank, river, lake, etc. It has optional output signal 4-20mA, RS485, HART, 2 relays or 3 NPN, optional power supply DC 12-16V, DC 24-28V, AC 220V or built-in battery.