Close
(0) Shopping cart
You have no items in your shopping cart.
Shopping Categories
Preferences
Search

Lab Water Purification System, <3ppb TOC, Type 1 & 3

5 out of 5 based on 1 reviews | Write a review
$6,028.90
Low TOC and pyrogen water purification system, RO Type I deionized ultra water purifier for lab, ultraviolet (UV) sterilized, IC automtical controling, used to IC/ICP-MS/HPLC/LC-MS organic analysis, TOC analysis, molecular biologu related experiment, e.g. PCR, DNA/RNA preparation, protein analysis and so on.
*
*
SKU: ATO-WPS-Mogene610
30-day Returns
Free Shipping
Delivery date: 6-12 days

Good quality reverse osmosis ultra-pure water system, for use with applications requiring Type 1 and Type 3 lab water, 18.25MΩ-cm@25℃ resistivity, removes particulates from feed water to less than 1 CFU/mL.

Specification

Model Mogene610s/ 620s/ 630s Mogene610d/ 620d/ 630d
Process Single pass RO system Double pass RO system
Output of pure water ≥10L/H ≥10L/H
Output of ultrapure water ≥ 1-1.5L/min ≥ 1-1.5L/min
Resistivity at 25℃ 18.25MΩ.cm 18.25MΩ.cm
Conductivity at 25℃ (Type 3 water) ≤10μs/cm ≤5μs/cm
TOC < 3ppb < 3ppb
Pyrogens/endotoxins < 0.025EU/ml < 0.025EU/ml
Bacteria < 1cfu/ml < 1cfu/ml
Particles (> 0.22μm) < 1/ml < 1/ml
Absorbance (254nm,1cm optical distance) ≤ 0.001 ≤ 0.001
Reactive Silica (SiO2) < 0.01ppm < 0.01ppm
Heavy metal < 0.01ppm < 0.01ppm
Electrical requirements 220V (230V, 240V) 50Hz
Power ≥100W ≥150W
Dimension (L/W/H) 340*550*530mm 340*550*530mm
Weight ≥34KG ≥45KG
Tank capacity  30L

Note: The model end with 's' has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm<TDS<400ppm. If feed water inlet TDS>400PPM, suggest an additional industrial type softener.

Product Features
Power-on self-test, water shortage protection alarm, power-off protection.
Built-in RO membrane anti-scaling program, RO membrane manual cleaning button.
Built-in automatic cycle timing of ultra pure water, ultra pure water conservation.
On-line monitoring of water resistance, real-time display of system operating status and warnings.
Pure water tank with cone type structure,a discharge valve at the bottom, easy to clean and disinfect exhausted.
Digital display the time of regular intake or conveying water pressure. Can set time of water outlet.

Lab Test and Corresponding Water Type List

Test Name Type III Water Type II Water Type I Water
Lab glassware washing    
Hydroponics    
Sterilizer use water    
Gas generator use water  
Conventional test    
Reagents/ drugs preparation, dilution    
Feed water for ultrapure water    
IC    
LC/LC-MS    
HPLC    
AAS    
ICP/ICP-MS    
GC/GC-MS    
Trace analysis    
TOC analysis    
Organic analysis    
Inorganic analysis    
Environmental analytical test    
Microelectronics parts cleaning    
Precision instrument use water    
Analytical reagent/ drugs preparation, dilution    
Mass spectrometry    
PCR application/analysis    
DNA/RNA research    
Proteomics research    
Plant and animal cell culture    
Toxicity analysis    
Microbiology experiment    
Immunological experiment    
Biochemistry experiment    
Serum test    
IVF    

Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)

No. Name Specification Lifespan
1 PP filter 1st stage, 10”/20” (5μm) 3-6 months
2 Activated Carbon filter 2nd stage, 10”/20” 6-12 months
3 Softener filter 3rd stage, 10”/20” 6-12 months
4 Precision filter 4th stage, 10”/20” (1μm) 10-12 months
5 RO membrane 75g/300g 1-2 years
6 Ultra purification resin column   1 year
7 Micro filter 0.22μm 1 year
8 UV lamp 185/254nm 8000 hours
9 Pure water tank 30L, 80L, 120L  

Tips: How to choose the right lab purification water system.
Uses: Different experimental projects have different requirements for the quality of produced water. Based on this, the appropriate machine model can be roughly determined. For example, the amount of Type 3 water used in the laboratory is relatively large, the amount of ultra-pure water is small, or only Type 2 or Type 1 water is used.
Water intake mode: whether to take water continuously or intermittently during work. Are there any special requirements for water pressure or water storage buckets, hoses, etc.
Water use during peak periods: duration of water intake peaks, water requirements, and water quality.
According to the daily water consumption, further determine the specifications of the required ultrapure water system.
Working environment: location, space, distance of water inlet and outlet, power supply, etc.

 

Existing reviews of Lab Water Purification System, <3ppb TOC, Type 1 & 3
Wonderful water purification system
We bought this water purification system for cleaning laboratory instruments. This is exactly what I want. Works great and runs without noise. The appearance is fashionable, the water flow meets the demand, and the TDS value after filtration is 0. It fully meets the experimental standard.
From: Matt | Date: 27/04/2022
Was this review helpful? Yes No (0/0)
Write your review for Lab Water Purification System, <3ppb TOC, Type 1 & 3
  • Only registered users can write reviews
  • Bad
  • Excellent