Close
(0) Shopping cart
You have no items in your shopping cart.
Shopping Categories
Preferences
Search

2kVA 120V to 120V/240V Split Phase Transformer

5 out of 5 based on 1 reviews | Write a review
$1,578.96
2kVA single phase to split phase isolation transformer winding material can choose copper wire or aluminum wire, transformer wheels and shell can be customized, input voltage AC 120V/220V/230V/440V/480V is optional, output voltage 120V/240V AC.
*
*
*
*
*
SKU: ATO-T-DGS2kVA
30-day Returns
Delivery date: 10-20 days

Best price isolation transformer capacity 2kVA, 1 phase to split phase, applies to AC 50/ 60Hz, convert primary voltage AC 120V to secondary voltage 120V/240V AC(L1、L2、N;L+L=240V,L+N=120V).

2 kVA Single Phase to Split Phase Transformer Specifications

Model ATO-DGS2kVA
Phase Single phase to split phase
Capacity 2 kVA
Primary Voltage 1 Phase / 2 phase 110, 120, 208, 220, 230, 240, 380, 415, 440, 460, 480,
Secondary Voltage 120V/240V AC(L1、L2、N;L+L=240V,L+N=120V)
Frequency 50/60Hz
Winding Material Aluminum/Copper wire (Optional)
Work Efficiency ≥95%
Insulation Resistance ≥50 MΩ
Electrical Strength 2000V AC/1 min
Noise ≤35dB (1 meter)
Insulation Grade Grade B (130℃), Grade F (155℃), Grade H (180℃)
Cooling Method Natural or air cooling
Overload Capacity Allow more than 1.2 times rated load to work for up to 1 hour
Induced Overvoltage Withstand Test 125Hz/800V/min
Transformation Ratio <3%
Air Carrying Current <6%
Impedance Voltage About 6%
Total Losses 10%
Certification CE, ISO
Temperature -15℃~+45℃
Humidity ≤90%RH, without condensation
Altitude <2000m, non corrosive gas and conductive dust
Enclosure Protection Grade IP20
Warranty 12 months
Weight of Aluminium Wire Transformer Open type: 37kg
Protected type: 55kg
Weight of Copper Wire Transformer Open type: 30kg
Protected type: 50kg

Single Phase to Split Phase Transformer Schematic Diagram
Single phase to split phase transformer schematic diagram
2 kVA Split Isolation Transformer Dimension (Unit: mm)
Split phase isolation transformer dimension

Aluminium Wire Transformer Size Copper Wire Transformer Size
Open type: a*b*c=210*230*230mm Open type: a*b*c=192*210*220mm
Mouting size: D*E=150*170mm (aperture: 17*8mm) Mouting size: 140*160mm (aperture: 17*8mm)
Protected type: A*B*C=300*440mm*500mm Protected type: A*B*C=300*440*500mm

 

Details

Single Phase Isolation Transformer Details

Tips: How to wire a dry-type transformer?

1. Use a megohmmeter to test the grounding resistance between the "input" and "output" wiring terminals of the wiring transformer. When the 1000V megohmmeter is accurately measured, the resistance value exceeds 2M ohms.
2. The cross-sectional wiring of the input and output power plugs of the transformer should be in accordance with the current size; it is advisable to configure it in accordance with the current intensity of 2-2.5A/min2.
3. The input and output three-phase power lines should be connected to phase A, phase B, and phase C respectively according to the yellow, green, and red color of the busway of the transformer terminal block. The neutral line should be connected to the neutral neutral line of the transformer. The ground line, The transformer case and its transformer points are connected to each other. The ground wire and neutral wire that everyone talks about are all led out by the neutral wire of the transformer. (For example, the transformer box should be connected with the ground wire of the shell to match). Check the input and output lines to make sure they are correct and correct.
4. First, plug in at full load and observe that the input and output voltages meet the requirements. At the same time, observe whether the equipment has abnormal noise, ignition, smell and other abnormal conditions. If there is any abnormality, please cut off the input switch power supply.
5. When the full load detection is performed and everything is normal, the load can be connected.

Existing reviews of 2kVA 120V to 120V/240V Split Phase Transformer
Can you provide isolation transformer with enclosure type: NEMA 4X FFT2?
Can you provide isolation transformer with enclosure type: NEMA 4X FFT2?
From: Drevell | Date: 15/11/2021
Was this review helpful? Yes No (0/0)
ATO Responded
No, our transformer cannot reach enclosure type: NEMA 4X FFT2, and the outdoor rainproof enclosure can only reach IP54.
Write your review for 2kVA 120V to 120V/240V Split Phase Transformer
  • Only registered users can write reviews
  • Bad
  • Excellent