    Current Transformer, 30/5A, 150/5A, 600/5A to 800/5A

    $38.67
    Current transformer at a low price, rated voltage up to and including 0.66 kV and rated frequency 50Hz. Current ratio can choose 50/5A, 100/5A, 300/5A, 600/A to 800/5A, and secondary burden select from 1, 0.5, 0.5S, 0.2, or 0.2S. High performance, small size and good safety.
    SKU: ATO-LMK1-0.66-40
    *
    *
    Delivery date: 6-12 days

    High accuracy current transformer light weight, small size and cheap price, current ratio 30:5A, 75:5A, 200;5A, 500:5A to 800:5A. Current transformer is mainly used for indoor or distribution box, rated frequency 50Hz.

    Specification:

    Product Name Current Transfer
    Model Number LMK1-0.66-50
    Weight 1 kg
    Current ratio (A) VA Secondary load/ Burden (VA) Cross-core turn number
    1 0.5 0.5S 0.2 0.2S
    30/5 5 5 5 5 5 5
    50/5 5 5 5 5 5 3
    75/5 5 5 5 5 5 2
    100/5 2.5 2.5       1
    150/5 5 5 5 5 5 1
    200/5 5 5 5 5 5 1
    300/5 5 5 5 5 5 1
    400/5 5 5 5 5 5 1
    500/5 5 5 5 5 5 1
    600/5 5 5 5 5 5 1
    700/5 10 10 10 10 10 1
    800/5 10 10 10 10 10 1
    Rated Frequency 50 Hz
    Rated Test Voltage 3kV AC (1min)                                                   
    Rated short-time thermal current (ith) 60 in
    Rated dynamic current (idyn) 2.5 lth
    Rated voltage (Um) 0.72 kV AC                     
    Continuous overload (ld) 1.2 in
    Operating temperature -10℃~50℃
    Housing self-extinguishing class VO
    Safety factor FS 5
    Secondary current 5A/ 1A
    Installation sites Indoor
    Ambient humidity ≦80%
    Altitude ≦1000m
    Atmospheric conditions No serious impurity in the atmosphere

     Current Transformer DimensionCurrent Transformer

    Tips: How to measure the polarity of current transformer?

    • DC Method
      Connect the positive and negative electrode of a 1.5~3V battery with the primary coil L1 and L2 of the transformer respectively, connect the transformer's secondary side K1, K2 respectively with the positive and negative electrode of a milliammeter. After the loop is well connected, the indicator of milliammeter turns clockwise while connecting K, and turns anticlockwise while disconnecting K, that means the transformer's terminal connecting with the positive electrode of the battery has the same polarity with the terminal connecting with the positive end of the milliammeter, namely L1 and K1 have a same polarity and the transformer is a subtractive polarity. If the indicator turns conversely to the above, the transformer is an additive polarity.
    • AC Method
      Connect the L2 and secondary side K2 of the current transformer's primary and secondary coil with wires, then add an 1~5V AC voltage to the secondary side, measure the U2 and U3 with a voltmeter below 10V, if U3=U1-U2, the transformer is a subtractive polarity; if U3=U1 U2, the transformer is an additive polarity.
    • Meter Method
      Generally, the transformer calibrator is equipped with a polarity indicator, it can test the polarity in advance before measuring the current transformer error. If the indicator has no indication, meaning that the polarity of the tested current transformer is correct. (subtractive polarity)
    Write your review for Current Transformer, 30/5A, 150/5A, 600/5A to 800/5A