$146.03
This handheld calibration tool is a voltage, current and thermocouple signal source/generator, able to output and measure 0-30V, 0-24mV, and 0-100mV voltage signal, 0-24mA and 4-20mA current signal and K, E, J, T, R, B, S, N type thermocouple, easy to use and high accuracy, helpful for testing and calibration in the industry field.
*
SKU: ATO-SIGNAL-C703
30-day Returns
Free Shipping
Delivery date: 6-12 days

This calibration tool outputs and measures voltage/current/thermocouple signal source, and features simple operation, long standby time, high accuracy and programmable output with LCD screen and silicone keyboard. It’s widely used for calibration or debugging in labs, PLC industry site, process instruments, electric valves and other areas.

Specification

Basic Information
Model ATO-C703
Main Functions Voltage signal: 0-30V, 0-24mV, 0-100mV output and measurement
Current signal: 0-24mA, 4-20mA output and measurement
Thermocouple: K, E, J, T, R, B, S output and measurement
Operating Temperature -10~55℃
Operating Humidity 20%~80%RH, non-condensing
Storage Tempeature -20~70℃
Size 115*71*30mm
Weight 300g
Power Supply 4 AAA batteries or 5V/1A power adapter
Power Dissipation 200mA, 4 hours under full load when powered by 4 AAA batteries (nominal capacity of a single battery is 1100mAh), and 17 hours in standby mode.
Battery Life 7~10 hours
Over Current Protection (OCP) 30V
Technical Parameters (Signal Output and Measurement Functions)
Item Signal Type Range Accuracy Resolution Remarks
DC Voltage 20mV 0.00-24.00mV ±0.1% 0.01mV /
100mV 0.00-100.00mV ±0.1% 0.01mV
V Output 0.00-15.00V ±0.1% 0.01V Output: 30mA maximum current
Measure: 1.2MΩ input impedance
Measure 0.00-30.00V ±0.1% 0.01V
DC Current mA 0.00-24.00mA ±0.1% 0.01A Output: 750Ω maximum load
Measure: 100Ω input impedance
4-20mA 4/8/12/16/20mA ±0.1% 0.01mA
Passive Current mA 0.00-24.00mA ±0.1% 0.01mA Output: 16-30V external power
Power Distribution Output 24VLOOP 24V/16V ±10% 0.1V Drive current 24mA
Thermocouple K -270~1372℃ ±1% 1℃ Output: range only from 0℃
E -270~1000℃ ±1% 1℃
J -210~1200℃ ±1% 1℃
T -270~400℃ ±1% 1℃
R -50~1768℃ ±1% 1℃
B 0~1820℃ ±1% 1℃
S -50~1768℃ ±1% 1℃
N -270~1300℃ ±1% 1℃

Selection table
There are also available with other calibrators/signal source generators with different functions. Please check the table below for more details. Buy a suitable one for routine maintenance of your devices.

Functions Signal Type Product Model (Optional) Accuracy
C703 C703S
DC Voltage


20mV Y Y ±0.2%
100mV Y Y
Output 0~15V Y Y
Measure 0~30V Y Y
DC Current mA Y Y
4~20mA Y Y
Passive Current mA Y Y
Power Distribution Output 24VLOOP Y Y ±10%
Thermocouple K/E/J/T/R/B/S/N Y Y ±1%
Thermal Resistance PT100 N/A Y ±0.2%
Resistance Ω N/A Y ±0.2%
Range Conversion mA Y Y /
Programmable Output / Y Y /

Note:
* For the specific parameters of the above functions, please click here.

Details

Handheld Voltage Current Thermocouple Calibrator Details

Tips: Troubleshooting & maintenance of C703 handheld signal source calibrator

1. Troubleshooting

  • Nothing displays on the LCD screen after turning on the signal source.
    a. Check if the battery is OK.
    b. Check if the power adapter outputs the current of 1000mA.
  • The measurement result cannot display.
    Make sure that the signal source calibrator is on the status of MEASURE.
  • The output or measure value is abnormal.
    a. Check if the signal wires are connected correctly.
    b. Make sure that the right signal type is chosen.

2. Maintenance

  • This handheld signal source calibrator is powered by 3.7V rechargeable lithium battery. For a long time use, please power it by power adapter so as to extend the lifespan of battery.
  • If you use a phone charger to charge the instrument, please confirm that the phone charger output current is 1000mA.
  • The instrument is not waterproof. Please keep it away from too humid environment.
Existing reviews of Handheld Voltage Current Thermocouple Calibrator, Output Signal Source
Great signal source
This handheld signal generator is right for me. It is small and easy to carry. Just put it in my pocket when I go to the industrial site. Besides, it is not too complex and I can operate this very well soon. Works as advertised.
From: Manu | Date: 24/10/2018
Was this review helpful? Yes No (1/0)
Write your review for Handheld Voltage Current Thermocouple Calibrator, Output Signal Source
  • Only registered users can write reviews
  • Bad
  • Excellent
Customers who bought this item also bought

Handheld Precision Multifunction Calibrator, Output Signal Source

$412.22
SKU: ATO-SIGNAL-LR-C512
This handheld multifunction calibrator is a high precision signal source/generator, designed to output variety of signals including DC voltage, DC current, resistance, RTD, thermocouple, pulse frequency, and power distribution, ideal tool for calibrating and troubleshooting detectors.