Close
(0) Shopping cart
You have no items in your shopping cart.
Shopping Categories
    Filters
    Preferences
    Search

    Lab Water Purification System for Biochemical Analyzer

    $5,456.56
    Excellent price lab RO water treatment equipment, specially made for blood station / research lab / clinical laboratory in hospital / biochemical analyzer, provides Type II and Type III deionized water, ≥ 5MΩ-cm resistivity, supplied to Roche, Hitachi, Olympus, Siemens, Mindray etc biochemistry analyzers.
    *
    *
    SKU: ATO-WPS-Mobiochem910
    30-day Returns
    Free Shipping
    Delivery date: 6-12 days

    High quality laboratory ultra-pure water system for biochemical analyzer matched used, adopt PP, AC filter, RO membrane, purification column, final filter and other technologies.

    Specification

    Model Mobiochem910s/ 920s/ 930s Mobiochem910d/ 920d/ 930d
    Process Single pass RO system Double pass RO system
    Water production capacity ≥10L/H ≥10L/H
    Water output rate 1-1.5L/min 1-1.5L/min
    Resistivity at 25℃ ≥5MΩ.cm ≥5MΩ.cm
    Absorbance (254nm,1cm optical distance) ≤ 0.01 ≤ 0.01
    Reactive Silica (SiO2) ≤ 0.02ppm ≤ 0.02ppm
    Heavy metal < 0.01ppm < 0.01ppm
    Electrical requirements 220V (230V, 240V) 50Hz
    Power ≥100W ≥150W
    Dimension (L/W/H) 490*550*850mm 490*550*850mm
    Weight ≥50KG ≥55KG
    Tank capacity 30L

    Note: The model end with 's' has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm<TDS<400ppm. If feed water inlet TDS>400PPM, suggest an additional industrial type softener.

    Product Features
    Power on self test, water shortage protection alarm, power-off protection.
    Built-in RO membrane fouling prevention program, auto flushing when open and manual RO membrane cleaning button.
    Built-in automatic cycle timing of ultra pure water, ultra pure water conservation.
    Water resistance/conductivity on-line monitoring, display the running state and parameters.
    Pure water tank with cone type structure, a discharge valve at the bottom, easy to clean and disinfect exhausted. Water level auto detection.

    Lab Test and Corresponding Water Type List

    Test Name Type III Water Type II Water Type I Water
    Lab glassware washing    
    Hydroponics    
    Sterilizer use water    
    Gas generator use water  
    Conventional test    
    Reagents/ drugs preparation, dilution    
    Feed water for ultrapure water    
    IC    
    LC/LC-MS    
    HPLC    
    AAS    
    ICP/ICP-MS    
    GC/GC-MS    
    Trace analysis    
    TOC analysis    
    Organic analysis    
    Inorganic analysis    
    Environmental analytical test    
    Microelectronics parts cleaning    
    Precision instrument use water    
    Analytical reagent/ drugs preparation, dilution    
    Mass spectrometry    
    PCR application/analysis    
    DNA/RNA research    
    Proteomics research    
    Plant and animal cell culture    
    Toxicity analysis    
    Microbiology experiment    
    Immunological experiment    
    Biochemistry experiment    
    Serum test    
    IVF    

    Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)

    No. Name Specification Lifespan
    1 PP filter 1st stage, 10”/20” (5μm) 3-6 months
    2 Activated Carbon filter 2nd stage, 10”/20” 6-12 months
    3 Softener filter 3rd stage, 10”/20” 6-12 months
    4 Precision filter 4th stage, 10”/20” (1μm) 10-12 months
    5 RO membrane 75g/300g 1-2 years
    6 Ultra purification resin column   1 year
    7 Pure water tank 30L, 80L, 120L  

    Tips: Laboratory purification water system freezes easily in winter.
    If the laboratory purification water system is installed outdoors, the necessary anti-freezing measures must be taken, otherwise this will cause damage to parts. Stop using the laboratory ultrapure water system as soon as the temperature is below 0 ° C.
    If it is installed indoors, the temperature must be higher than 0 ℃. If the temperature is too low, the pipes will be cracked and leak.
    If you do not use for a long time or need to go out, you must close the water inlet valve to drain all the water from the device.
    If you encounter icing, you need to place the entire device in a room with a temperature higher than 10 ° C for 48 hours before you can continue to use it. During this thawing period, do not open the machine.

    Write your review for Lab Water Purification System for Biochemical Analyzer
    • Only registered users can write reviews
    • Bad
    • Excellent