1/2 hp VFD, Single Phase to Three Phase VFD

4.9 out of 5 based on 10 reviews | Write a review
$149.10
1/2 hp VFD, convert single phase to three phase for AC motor speed controls, 208V - 240V 3 amps, IP20, RS485 enabled, manufacturer direct sale.
SKU: GK3000-2S0004
Availability: In stock
30-day Returns
Free Shipping
Delivery date: 2-12 days

1/2 hp VFD, 0.4 kW, 208V - 240V single phase to three phase variable frequency drive, sale by manufacturer directly.

Specification:

Basics Model GK3000-2S0004
Capacity 1/2 hp (0.4 kW)
Shipping weight 2 kg
Dimension 142*85*110 mm
I/O Feature Rated current 3 A
Input voltage 1 phase 220~240V AC
Input frequency 50Hz/ 60Hz
Output voltage 3 phase AC 0~input voltage
Output frequency 0Hz~1000Hz
Over load capacity 150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control Feature Control mode V/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Communication RS485
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity 5%-95%, without condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Impingement and oscillation Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

400W VFD Single Phase to Three Phase VFD Details

Tips: Variable frequency drive hardware replacement precautions

  1. Replace the IGBT. Measure whether the resistance value of each road is balanced.
  2. Replace the drive board. Need to carefully check whether the plug and socket number is consistent.
  3. Replace the main control board. After replacing the main control board, set the application parameters, motor parameters and protection parameters of VFD.
  4. Replace the PG card. Check whether the terminals are normal. If the motor has a vibration or cannot rotate after replacing the card, need to exchange the A and B phase.
  5. Replace the communication board. Simply check the DIP switch set by VFD hardware station number, and then check that the communication light is normal.
  6. The communication board of some VFD series is an independent CPU. After the replacement, need to upload configuration program.
Existing reviews of 1/2 hp VFD, Single Phase to Three Phase VFD
VFD recommendation
I have a three-phase, 220-volt, 4-kilowatt table saw that needs to be powered by a 220-volt single-phase power supply. I want to be able to stop it relatively quickly, and may need an external resistor. I hope you can give me a recommendation on this.
From: Howard | Date: 08/04/2025
Was this review helpful? Yes No (0/0)
ATO Responded
How quickly the motor stops depends on the size of the mechanical inertia. The larger the mechanical inertia, the larger the busbar, the larger the current, and the slower it stops. It is impossible to determine how large a resistor is needed. Our VFD manual defaults to a braking resistor power of 10% of the inverter power for reference.
The factory reset parameter
What is the factory reset parameter for the ATO GK3000?
From: Danica | Date: 14/09/2024
Was this review helpful? Yes No (0/0)
ATO Responded
Restore factory settings: If your VFD nameplate has 9000, please set Pd.01=1. If the nameplate does not have 9000, please set parameter P3.01=10.
We need help
We installed a GK3000. It has not gone well. We need help. How do we increase output voltage? We need a minimum of 208V, we are only getting 195. There is 240 going in. Got it to the “fun” stage several times but no further. Output reads low. We would appreciate any assistance you can provide.
From: Lao | Date: 16/08/2024
Was this review helpful? Yes No (0/0)
ATO Responded
If your VFD has the number 9000, then you need to set the parameter P8.02=220V.
If your VFD does not have the number 9000, then you need to set the parameter P0.08=220V.
In addition, the output frequency needs to reach the upper limit frequency (rated frequency) for the output voltage to reach 220V.
Load more reviews...
Write your review for 1/2 hp VFD, Single Phase to Three Phase VFD
  • Only registered users can write reviews
  • Bad
  • Excellent
Customers who bought this item also bought

2 hp VFD, Single Phase to Three Phase VFD

$183.16
SKU: GK3000-2S0015
2 hp VFD, convert single phase to three phase for AC motor speed controls, 7 amps, IP20, RS485 enabled, manufacturer direct sale.

1 hp VFD, Single Phase to Three Phase VFD

$159.32
SKU: GK3000-2S0007
1 hp VFD, convert single phase to three phase for AC motor speed controls, IP20, RS485 enabled, shipping weight 2kg, manufacturer direct sale.