Close
(0) Shopping cart
You have no items in your shopping cart.
Shopping Categories
Preferences
Search

10kVA Control Transformer, 230V to 110/36V

5 out of 5 based on 1 reviews | Write a review
$1,721.54
Best and cheap industrial control low voltage transformer used in 50Hz/60Hz, has 10kVA power rating, designed to step down single phase 230 volt primary voltages to 110/36V dual secondary voltage, fully electric isolation between primary side and secondary sides.
*
*
*
SKU: ATO-T-BK10KVA
30-day Returns
Delivery date: 6-12 days

230V to 110/36V 1 phase control transformer on sale, features 10kVA capacity, high quality terminal block, high temperature resistance, worked as control power supply for mechanical equipment and general electrical appliance. Primary and secondary voltages are customizable and but should be noted that primary voltage not exceed 500V, secondary voltage not exceed 240V.

Specifications

Product Name Single phase control transformer
Product Model ATOBK-10KVA
Winding Material* Enameled copper wire or enameled aluminum wire (Optional)
Total Output Capacity 10kVA
Note: (If your output includes multiple voltage levels, please email us with the capacity of each output. The total capacity should be the sum of all individual outputs. For example, if your outputs are aV and bV, then aV (capacity) + bV (capacity) = 10kVA).
Primary Voltage* (VAC) 110, 120, 208, 220, 230, 240, 380, 400, 480, 110/220, 120/240, 240/480...(Optional and Customized)
Secondary Voltage* (VAC) 6, 12, 24, 36, 48, 110/48, 120/24, 208/36, 220/48, 230/36, 240/120, 120/24/12, 110/36/24, 127/36/6, 208/48/36/24...(Optional and Customized)
Frequency 50 / 60Hz
Insulation Level F / H
Withstand Voltage Test Primary to secondary 2.5KV/min
Primary to safety ground 2.5KV/min
Secondary to safety ground 1.5KV/min
Insulation Resistance Primary to secondary 2500V>100 megohm
Primary to safety ground 2500V>100 megohm
Secondary to safety ground 1500V>100 megohm
Induction Withstand Voltage Test 125Hz/ 800V/min
Ground Resistance 25A<80 milliohm
Cooling Method Natural or air cooling
Transformation Ratio <3%
Air Carrying Current <6%
Impedance Voltage about 6%
Total Losses 0.1
Efficiency 80%~99%
Operating Temperature -25℃~40℃ (40℃, 93% RH, 56 days)
Storage Temperature -25℃~100℃ (40℃, 93% RH, 56 days)
Certificate CE, ISO
Warranty 12 months
Size Overall size: 290*240*330mm, Hold distance for installation: 150*180mm, Installation hold: 20*10mm
Weight 80kg

Schematic diagram illustration

Control transformer schematic diagram illustration

 Control transformer dimension

Control transformer dimension

Overall size (mm) Hole distance for installation (mm) Installation hole (mm)
B E D A C K x J
290 240 330 150 180 20 x 10

Tips: How to dry a control transformer?

There are two methods of controlling transformer drying: One is the induction heating method, and the other is hot air drying method.

1. Induction heating method

This method is to place the body in the oil tank, apply power frequency current to the outer winding coil, and use the heat of eddy current loss in the oil tank wall to dry. At this time, the temperature of the box wall shall not exceed 115℃ ~ 120 ℃, and the temperature of the body shall not exceed 90℃ ~ 95 ℃. For the convenience of winding the coil, the number of turns of the coil shall be as small as possible or the current shall be as small as possible. Generally, the current shall be 150A, and the conductor can use 35-50mm conductor. The oil tank wall can be padded with several asbestos strips, and the wires are wound on the asbestos strips.

2. Hot air drying method

This method is to put the body in the drying room and dry it with hot air. The temperature of hot air at the inlet shall gradually rise, and the maximum temperature shall not exceed 95 ℃. A filter shall be installed at the inlet of hot air to prevent sparks and dust from entering people. Do not blow hot air directly to the body. Try to blow it evenly from the bottom of the body to all directions, so that the moisture will be released from the vent hole of the box cover.

Existing reviews of 10kVA Control Transformer, 230V to 110/36V
Good quality and low price
This 10kVA control transformer is stable in operation, easy to install, does not take up much space, and does not overheat even when it is running for a long time. I am very satisfied with it after using it for a period of time, and it is cost-effective.
From: Cecilia | Date: 26/02/2025
Was this review helpful? Yes No (0/0)
Write your review for 10kVA Control Transformer, 230V to 110/36V
  • Only registered users can write reviews
  • Bad