    60 kVA Isolation Transformer, 480V 3 phase to 220V 3 phase

    $5,516.92
    ATOSG-60KVA isolation transformers is 50/60 Hz rated, it can change 3 phase 480V AC to 3 phase 220V and come in a NEMA 3R enclosure for indoor use as well as outdoor protection against rain and sleet.
    SKU: ATOSG-60KVA
    Delivery date: 6-12 days

    60 kVA, 3 phase 480V to 220V isolationt ransformers from ATO that is of superior quality. It is manufactured using high grade components and the latest technology to ensure high durable finish standards, maintenance free working, and high load capacity.
    Specifications

    Basics Model ATOSG-60KVA
    Phase 3 phase
    Capacity 60 kVA
    Size 700*320*660 mm (without shell); 1000*500*1050 mm (with shell)
    Weight 370 Kg (without shell); 440 Kg (with shell)
    Technical Parameters Primary Voltage 480V (optional: 110V/ 120V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V)
    Secondary Voltage 220V (optional: 110V/ 120V/ 208V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
    Voltage Convert Single phase to single phase, three phase to three phase, three phase to single phase
    Frequency 50Hz / 60 Hz
    Work Efficiency ≥95%
    Insulation Resistance ≥5 MΩ
    Electrical Strength 3000V AC/1 min
    Noise <35-65dB (1 meter)
    Insulation Grade H level
    Wiring Mode Dyn11
    Cooling Mode Dry type air cooling
    Overload Capacity Allow more than 1.2 times rated load to work for up to 4 hours
    Working Environment Temperature -15℃~+40℃
    Humidity ≤90%RH, without condensation
    Altitude <1000m, non corrosive gas and conductive dust

    Note:
    Transformer can only convert voltage and CANNOT convert frequency.
    Transformer CANNOT convert single phase voltage to 3 phase voltage.
    Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.
    Product Application Areas
     isolation transformer application fieldTips: Oil make-up of transformer operation, what should be paid attention to?
    Transformer oil make-up can be carried out without transformer electricity cut. Pay attention to the following matters during oil make-up:

    1. Pay attention to avoid mixing the oil, the new added oil should pass the test.
    2. Heavy gas protection should be changed to the signal position before oil make-up so as to prevent the gas protection from malfunctioning and tripping the transformer.
    3. Pay attention to check the gas relay after oil make-up and release the gas in time. Only after the air of the transformer is exhausted can the heavy gas protection be re-put to the trip position.
    4. Make up the appropriate amount of oil, the oil level should fit the transformer oil temperature.
    5. It is forbidden to make up oil from the lower stop valve of the transformer to prevent the sediment at the bottom of the transformer from being washed into the coil, which will affect the insulation and heat dissipation of the transformer.
    Write your review for 60 kVA Isolation Transformer, 480V 3 phase to 220V 3 phase
    • Bad
    • Excellent