    125 hp (90 kW) VFD, 3 Phase 220V, 415V, 480V

    5 out of 5 based on 2 reviews | Write a review
    $3,741.60
    Cheap price 125 hp (90 kW) VFD for induction motor speed controls, three phase 220V, 415V, 480V energy saving variable frequency drive, direct sale by manufacturer in wholesale price.
    SKU: GK3000-4T0900G
    30-day Returns
    Free Shipping
    Delivery date: 6-12 days

    125 hp heavy duty variable frequency drive, three phase 220V, 415V, 480V for selection, brand new direct sale by manufacturer.

    Specification:

    Basics Model GK3000-4T0900G/ GK3000-2T0900G
    Capacity 125 hp (90 kW)
    Shipping weight 51 kg
    Dimension 650*400*300 mm
    I/O Feature Rated current 176A at 380V ~ 480V, 380A at 220V ~ 240V
    Input voltage 3 phase 220V /415V /480V AC ±15% (Optional)
    Input frequency 50Hz/ 60Hz
    Output voltage 3 phase AC 0~input voltage
    Output frequency 0Hz~1000Hz
    Over load capacity 150% of rated current for 1 minute, 180% of rated current for 3 seconds
    Control Feature Control mode V/F control;
    Sensorless vector control;
    Communication RS485
    Speed regulation 1:100
    Start torque 150% of rating torque at 1 Hz
    Speed control accuracy ≤±0.5% of rating synchronous speed
    Frequency precision Digital setting: max frequency x± 0.01%;
    Analog setting: max frequency x± 0.2%
    Frequency resolution Analog setting: 0.1% of max frequency;
    Digital setting: 0.01Hz
    Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
    Interior PID controller Be convenient to make closed-loop system
    Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
    Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
    Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
    Environment Enclosure rating IP 20
    Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
    Humidity 5%-95%, without condensation
    Altitude ≤1000m; VFD will be derated if above 1000m
    Impingement and oscillation Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
    Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

    Tips: Variable frequency drive loading debugging process

    1. Manually operate the stop button of the inverter panel to observe the stopping of the motor and the display window of the inverter to see if there is any abnormality.
    2. If the VFD has overcurrent protection during motor stopping, the acceleration deceleration time should be reset. If the overcurrent occurs during the start-up process, the acceleration time may be extended. If the overcurrent occurs during the braking process, the deceleration time should be extended.
    3. If the VFD is still protected in the limited time, change the stopping operating curve from straight to S-shaped, U-shaped or S-shaped, anti-U-shaped.
    4. If the VFD still has a running fault, try to increase the maximum current protection value, but cannot cancel the protection, and should leave at least 10% to 20% protection margin.
    5. If the Problem still cannot be solved, replace a higher power VFD.
    6. If the VFD drives the motor in the boot process does not reach the preset speed, there may be two cases:
      (1) Electromechanical resonance occurs in the system, which can be judged from the sound of the motor. Depending on the frequency of the system, set the jump across and span on the VPf curve. When the motor is accelerating, it will automatically skip these frequency segments to ensure properly operation.
      (2) If the motor torque output capacity is not enough, the manual torque lifting function can be set. The set value should not be too high, or the motor temperature will be increased. If it still have problem, should use VPf ratio constant method, or switch no-speed sensor space vector control method. For fan and pump loads, should reduce the curve values of the torque reduction.
    Existing reviews of 125 hp (90 kW) VFD, 3 Phase 220V, 415V, 480V
    Do you accept credit card for instant payments?
    Do you accept credit card for instant payments?
    From: Gabriele | Date: 18/01/2022
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Yes, you can place your order directly online at our web site by credit card.
    125hp VFD shipping to New Zealand
    Are you sure the shopping of this 125 hp VFD is free of charge to New Zealand?
    From: Matthew | Date: 27/04/2018
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Yes, we confirm shipping is free of charge to New Zealand.
    Load more reviews...
    Write your review for 125 hp (90 kW) VFD, 3 Phase 220V, 415V, 480V
    • Only registered users can write reviews
    • Bad
    • Excellent