    16 amp 4 pole Miniature Circuit Breaker

    5 out of 5 based on 2 reviews | Write a review
    $79.29
    Economical price 16 amp 4 pole miniature circuit breaker complies with the IEC standard and is designed for mounting on a standard rail. This C16 mini MCB features a 6kA short-circuit interrupting capacity, ensuring reliable protection against short circuits and overloads in an AC 50Hz circuit.
    SKU: ATO-MCB-4P16
    30-day Returns
    Free Shipping
    Delivery date: 6-12 days

    16 amp 4 pole miniature circuit breaker is equipped with a C curve trip characteristic, which provides a balanced response to both overload and short-circuit conditions. This design of the C16 mini MCB ensures the safety and longevity of electrical systems, effectively safeguarding equipment from potential electrical faults.

    4 Pole MCB Breaker Information

    • Rated Current: 16 amp
    • Rated Voltage: 230/400V AC, 50Hz
    • Number of poles: 4 pole
    • 6 kA rated short-circuit breaking capacity
    • Compliant with IEC standard
    • C curve trip characteristic
    • With overload protection and short circuit protection function

    Technical Data

    Model ATO-NB8-634PC16
    Rated Current 16A
    Rated Voltage 230/400V
    Frequency 50Hz
    Number of Poles 4P
    Mechanical Life 20000 Times
    Electrical Life 10000 Times
    Rated Short-Circuit Breaking Capacity 6000A
    Operating Short-Circuit Breaking Capacity 6000A
    Rated Impulse Withstand Voltage (1.2/50) 6kV
    Dielectric Test Voltage 2000V (50Hz, 1 min)
    Heat & Humidity Resistance 28 Cycles
    Vibration Resistance No Obvious Vibration and Impact
    Terminal Block Terminal Block Type Pillar Terminal Block
    Min. Terminal Size Acceptability 1mm2
    Max. Terminal Size Acceptability 25mm2
    Standard Connection Torque 2 N.m
    Max. Tolerable Torque 2.5 N.m
    Wire Insertion Depth 13mm
    Reference Temperature 30℃
    Operating Temperature -35℃~+70℃
    Storage Temperature 35℃~+85℃
    Applicable Altitude 2000m
    Tripping Mode Thermal Magnetic Trip
    Electromagnetic Tripping Type Type C (5In-10In)
    Shell Flame Retardant Grade V0
    Wire Entry Method Both Upper and Lower
    Installation Method TH35-7.5 Standard Rail
    Protection Level Direct Installation IP20B
    Installed in the Distribution Box IP40B


    4 Pole MCB Breaker Dimensions (Unit: mm)

    16 amp 4 pole Miniature Circuit Breaker Dimensions

    Details

    4 pole Miniature Circuit Breaker Details

    Tips: 16 amp 4 pole miniature circuit breaker applications

    A 16 amp 4-pole miniature circuit breaker (MCB) is typically used in industrial and commercial electrical systems for protecting circuits against overcurrent and short circuits. Its 4 pole configuration is ideal for three-phase systems with a neutral line, protecting all conductors in the circuit (three phases and neutral).

    Common applications include:

    • Power Distribution Panels: Protecting circuits that supply machinery or equipment, ensuring the safety of both electrical installations and operators.
    • Motor Protection: Safeguarding three-phase motors that require simultaneous protection of all phases and the neutral.
    • UPS Systems: Protecting uninterruptible power supplies, ensuring safe shutdown and preventing damage to sensitive electronics during faults.
    • Renewable Energy Systems: In solar or wind power installations, providing overcurrent protection to the inverter and associated wiring.

    The 16 amp rating indicates it’s suitable for medium-sized systems, offering reliable protection without unnecessary tripping. Always ensure the breaker’s ratings match the circuit load to avoid damage.

    Types of Circuit Breakers

    In this video, we'll take a closer look at the meaning behind these abbreviations and explain the types of circuit breakers they represent. By understanding the different types of circuit breakers on the market, you can make an informed decision and choose the right type for your specific requirements, thereby enhancing the protection of your electrical infrastructure.

    Isolator vs Circuit Breaker

    Although isolators and circuit breakers have similar functions in a circuit, they are two separate entities. This video explains you the difference between the two devices in terms of working, features, operation, affordability, etc. You can choose between them based on your specific requirements.

    Existing reviews of 16 amp 4 pole Miniature Circuit Breaker
    This MCB is perfect for my applications.
    This 16 amp 4 pole miniature circuit breaker can protect my solar controller from damage by disconnecting solar power panel until battery connection is made. Perfect for my applications. Very pleased with this order and I would buy more if I need.
    From: Alexander | Date: 28/06/2022
    Was this review helpful? Yes No (0/0)
    Worked perfectly for my application.
    I bought this miniature circuit breaker last week. I used it as a switch on the DC input side of my PV charge controller. The DIN rail is wide enough for installing a protector next to it. I am happy with this purchase. I will buy again from ATO.com.
    From: Tambor | Date: 20/04/2022
    Was this review helpful? Yes No (0/0)
    Load more reviews...
    Write your review for 16 amp 4 pole Miniature Circuit Breaker
    • Only registered users can write reviews
    • Bad
    • Excellent