7.5kW AC Synchronous Generator, 1-phase/ 3-phase

5 out of 5 based on 1 reviews | Write a review
$1,673.97
7.5kW single phase/ three phase AC synchronous generator with cheap price for sale. Brush AC generator featuring rated capacity 9.4kVA, rated current 13.5A, 0.8 cosφ power factor, frequency 50Hz. Direct current generator is widely used in industrial and agricultural production, national defense, science and technology and daily life.
*
SKU: ATO-ASG-STC-7.5
30-day Returns
Free Shipping
Delivery date: 6-12 days

Good price brush AC generator with 1500 r/min rated speed, 4P, rated voltage single phase 220V/ 230V/ 240V, three phase 380V/ 400V/ 460V. Alternating current generator has an elegant appearance, sturdy and durable structure, convenient maintenance and long service life.

Specification

Model ATO-STC-7.5
Rated power 7.5kW
Rated capacity 9.4kVA
Rated current 13.5A
Power factor 0.8 cosφ
Pole number 4 pole
Rated speed 1500 r/min
Phase Single phase/ Three phase
Rated voltage 220V (230V/ 240V can be customized)/ 380V (400V/ 460V can be customized)
Frequency 50Hz
Weight 78kg
Certificate CE
Warranty 12 months

Dimension

Dimension of AC synchronous generatorDimension of AC synchronous generator

Model Mounting dimensions (mm) Outer dimensions (mm)
A B C D E F G H K a b h1 h L1 L2 g
STC-7.5 254 254 108 38 80 12 33 160 16 50 310 25 58 580 325 41

Tips: Normal Maintenance of AC Synchronous Generator.

Test the AC generator once a week with no load and run for 10-15 minutes in order to discover problems in time and ensure that the battery has sufficient capacity for the generator to start.
1. Before maintenance, the automatic air switch of the brush AC generator should be cut off, the main switch should be placed in the stop position, and the positive and negative power cords of the battery should be folded to confirm that the generator cannot be started.
2. Check the battery electrolyte level, if it is insufficient, add sulfuric acid solution or distilled water according to its concentration.
3. Calculate the cumulative running time of the generator from the last time. The air filter should be cleaned every 50 hours, and the oil filter, diesel filter, and water filter should be replaced every 250 hours.
4. Check whether the unit has water or oil leakage, and clean the generator body.
5. Connect the battery power cord and connectors properly, and the test failure indicator lights should all be on.

Existing reviews of 7.5kW AC Synchronous Generator, 1-phase/ 3-phase
Powerful 7.5kw synchronous generator
I bought this AC synchronous generator for replace my broken one, The generator arrived on time and worked well so far. Will recommend.
From: Herrera | Date: 20/06/2022
Was this review helpful? Yes No (0/0)
Write your review for 7.5kW AC Synchronous Generator, 1-phase/ 3-phase
  • Only registered users can write reviews
  • Bad
  • Excellent