    Digital Counter, 6 Digit, Up/Down, Number/Length/Batch

    $57.14
    6 digit counter can be used for counting number/length/batch, position control of balers controlled by variable frequency motor, and measuring height, position and angle. Digital counter with up/down input modes can preset count value or length, and simultaneously display the total count, counting length and batch value in real time.
    SKU: ATO-DIGC-FH6
    *
    *
    *
    *
    *
    *
    *
    *
    Free shipping
    Delivery date: 6-12 days

    Digital counter has 6 digit display, 4 kinds of up/down input modes, DC 12V/24V external power supply.

    Features:

    • Digital counter accuracy: 0.01%, minimum resolution: 0.0001.
    • Input/output signals photoelectric isolated, anti-interference ability.
    • Input: 4 kinds of input modes, a variety of input signals, various waveform pulse, grating, proximity sensors, photoelectric sensors, contact switches, encoders, etc. (NPN, PNP).
    • Output: 8 kinds of output modes to select, up to 3 segments control output, suitable for various control requirements.
    • 6 digit display, has external power supply DC 12V/24V/30mA especially for sensor.
    • Standard RS232 or RS485 MODBUS RTU communication, can be directly connected with computers, PLC or other equipments.

    Specification:

    Mode ATO-DIGC-FH6
    Weight 300g
    Accuracy 0.01%
    Power supply AC 90-260V, or AC/DC 12-30V/DC 24V, power dissipation≤5VA
    Input signal Pulse signal, square wave, sine wave, 5V≤H≤30V, 0≤L≤2V, rising edge trigger, frequency: 0.01~9KHz
    Counting rate ≤5000 CPS (Software selectable)
    Display counting range -199999~999999
    Ratio setting range 0.00001~99999.9
    Input impedance ≥10KΩ
    Relay output method R, N, C, F, H, L (count), upper and lower limits alarm, capacity AC 250V/3A, DC 30V/3A COSΦ=1
    Transmission output 4-20mA, 0-10V, etc. (range can be set)
    Insulation resistance ≥100MΩ (between DC 500V power terminal and external terminal)
    Dielectric strength AC 1500V 1min (between power terminal and external terminal)
    Environment Ambient temperature: 0~50°C, relative humidity: 35~85%RH
    External power supply DC 12V±5%, 50mA max / DC 24V±5%, 30mA max
    Protection class IP65

    Selection table:

    Dimention (length*height*depth) Power supply Function AL1 AL2 Communication interface External power supply Input signal
    4: 48*48*80mm with hole size 45*45mm;
    7: 72*72*80mm with hole size 67.5*67.5mm;
    8: 96*48*80mm with hole size 92*45mm
    V0: AC 90-260V;
    VE: AC/DC 12-30V, or DC 24V
    C: Number/length;
    B: Batch;
    P: Position control
    N: No output;
    R: Relay;
    S: SSR/LOGIC
    N: No output;
    R: Relay;
    S: SSR/LOGIC
    C0: No communication;
    C2: RS232;
    C4: RS485
    A: DC 12V/30mA;
    B: DC 24V/30mA;
    C: DC 5V
    I0: Two pulse inputs (encoder);
    I1: INA (one input for switching input)

    Digital counter up/down input modes:
    Mode A: Up (addition)
    INA counts up. INB is GATE function. When INB is high level (or shorted with +12V), INA input is forbidden.
    Digital counter up down mode a
    Mode B: Up/down (addition or subtraction)
    INA counts up. INB is count-down control function. When INB is high level, INA turns count-up into count-down.
    Digital counter up down mode b
    Mode C: Up/down (addition and subtraction)
    INA counts up, INB counts down.
    Digital counter up down mode c
    Mode D: Up/down (for encoder)
    INA signal leads INB signal (count-up). INA signal lags INB signal (count-down). It is often used for encoder or grating input.
    Digital counter up down mode d
    Wiring diagram:
    Digital counter up down wiring diagram
    Tips: Digital counter application in positioning and speed regulation of elevator
    The leveling signal of elevator is obtained by the position sensors installed in the elevator well. When there are many floors, the number of such signals is large, and there are certain difficulties in equipment installation and maintenance. At the same time these signals take up a lot of PLC input port. If using PLC and high-speed counter for positioning, it can not only solve these problems, but also can achieve frequency control of elevator.
    When the elevator is running, digital counter completes the counting work driven by the optical encoder. When the elevator car rises, digital counter counts up. When the elevator car goes down, digital counter counts down. The current value of the counter is the exact position of the car in the elevator well. In this way, the accurate positioning of the elevator is realized. This positioning method has the following functions: It realizes the floor digital display of the elevator lobby and car, determines the running direction, and determines the braking time of leveling.