Basics |
Model |
ATO-DR-60-24 |
Dimension |
78*93*56mm (W*H*D) |
Weight |
0.3kg |
Output |
DC Voltage |
24V |
Rated Current |
2.5A |
Current Range |
0~2.5A |
Rated Power |
36W |
Ripple & Noise (max.)( Note 2) |
150mVp-p |
Voltage Adjust Range |
21.6~26.4V |
Voltage Tolerance (Note 3) |
±1.0% |
Line Regulation |
±1.0% |
Load Regulation |
±1.0% |
Setup, Rise, Holdup time(Typ.) |
100ms, 30ms, 300ms /230V AC 200ms, 30ms, 23ms/115V AC at full load |
Input |
Voltage Range |
88 ~ 264V AC or 124 ~ 370V DC |
Frequency Range |
47~63Hz |
Efficiency(Typ.) |
84% |
AC Current(Typ.) |
1.2A/115V AC 0.8A/230V AC |
Inrush Current (Typ.) |
Cold start, 18A/115V AC; 36A/230V AC |
Protection |
Overload |
105~160% rated output power |
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
Overvoltage |
27.6 ~ 32.4V |
Protection type: Shut down O/P voltage, clamping by zener diode |
Safety & EMC |
Safety Standards |
Approved by UL60950-1, TUV EN60950-1, design refer to En50178 |
Withstand Voltage |
I/P-O/P:3KVAC |
Isolation Resistance |
I/P-O/P:100M Ohms / 500VDC / 25°C/ 70% RH |
EMC Emission |
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B,EN61000-3-2,-3 |
EMC Immunity |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A |
Environment |
Working Temperature |
-20 ~ +60°C (Refer to output load derating curve) |
Working Humidity |
20~90% RH (non-condensing) |
Storage |
Temperature |
-40~+85°C |
Humidity |
10~95% RH (non-condensing) |
Temperature Coefficient |
±0.03%/°C (0~50°C) |
Vibration |
Component |
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes |
Mounting |
Compliance to IEC60068-2-6 |
MTBF |
216.2K hrs min. MIL-HDBK-217F (25“C) |
Note |
1. All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance includes set up tolerance, line regulation and load regulation. 4. The switching power supply is considered a component which will be installed into final equipment. Please make sure that the final equipment still meets EMC directives. |