ATO level sensors are used for monitoring liquid or solid levels in tanks, reservoirs, and industrial storage systems. They provide continuous measurement or point-level detection for process control, alarms, and pump management.
Level sensing technologies fall into two primary categories: continuous (measuring the exact volume or height) and point-level (detecting an overflow or empty state).
Continuous Level Measurement
Used for real-time level monitoring across the full range.
Point-Level Measurement (Switching)
Point level measurement indicates when a product is present at a certain point, and continuous level measurement indicates the continuous level of a product as it rises and falls.
The table below provides a quick overview of different level sensor types to help you select the most suitable solution based on application and measurement requirements.
Continuous Level Sensors
| Capacitive Level Sensor |
Model SKU | Measuring range | Working temperature | Power supply | Output signal | best for |
| ATO-LEVS-900 | 0–900mm | -40°C~+85°C | 15~30V DC | 4–20mA /RS485/RS232/0–5V | Water level sensors in rivers, reservoirs, and power plants. | |
| ATO-LEVS-1000 | 0–1000mm | -20°C~+85°C | 9~30V DC/15 ~30V DC | 4–20mA/RS485/RS232/0-5V DC/0-10V DC | Oil tank and gas tank level measurement in industrial storage systems. | |
| ATO-LEVS-2000 | 0–2000mm | -50°C~+200°C | 9~30V DC/15~30V DC | 4-20mA/0-5V DC/0-10V DC | Diesel and gasoline fuel tank level measurement for generators. | |
| ATO-LEVS-GLTV7S | 100–1400mm | -35℃~70℃ | 9–30V DC | 4–20mA/RS485/RS232/0–5V | Hydraulic system oil level monitoring and machinery fluid control. | |
| Submersible Level Sensor |
ATO-LEVS-S200M | 0–200m | 0°C~+60°C | 12–24V DC | 4–20mA/RS485/0–5V | Underwater water level monitoring in wells, tanks, and reservoirs. |
| ATO-LEVS-CYW71 | 0~20~200kPa | -40°C~85°C | 9–28V DC | 4–20mA/RS485 | Acid and alkali liquid level detection in corrosive environments. | |
| ATO-LEVS-HT20M | 0–20m | -20°C~+85°C | 12–24V DC | 0-20mA/4-20mA/0-5V/0-10V | High temperature liquid level monitoring in boilers and industrial tanks. | |
| Ultrasonic Level Sensor |
ATO-LEVS-05 | 0–5m | –20°C to +60°C | 12V DC/24V AC/220V AC | 4–20mA | water level sensor for reservoirs, and chemical containers. |
| ATO-LEVS-U40M | 0–40m | –20°C to +60°C | 12-16V DC/24-28V DC/220V AC | 4–20mA/RS485/HART | Water level measurement in rivers, sewage tanks, and outlet water systems. | |
| ATO-LEVS-U60M | 0–60m | -20°C~+80°C | 24V DC/220V AC | 4–20mA / RS485/RS232 | Ultrasonic level sensor for diesel tank, oil, and mixed liquid storage tanks. | |
| ATO-LEVS-NC | 0–20m | -40°C~80°C | 24V DC | 4–20mA | Acid-alkali liquid storage tanks, water level of wells. | |
| ATO-LEVS-CS03 | 5–30m | –20°C to +60°C | 12–30V DC | 4–20mA/RS485/RS232 | Wastewater, sludge, and adhesive liquid level monitoring. | |
| ATO-LEVS-FK | 5–15m | -20°C~+80°C | 250V AC/3A | 4–20mA/RS485 | Suitable for a wide range of industrial scenarios. | |
| Radar Level Sensor |
ATO-LEVS-RD902 | 0–30m | -40℃~+250℃ | 12-24V DC/220V AC | 4–20mA/RS485/HART | High-temperature and pressure liquid level measurement in industrial environments. |
| ATO-LEVS-RD901 | 0–10m | -40°C~+150°C | 12-24V DC/220V AC | 4–20mA/RS485/HART | Corrosive liquid level monitoring in chemical and storage systems. | |
| ATO-LEVS-RD909 | 0–70m | -40°C~+150°C | 12-24V DC/220V AC/50Hz | 4-20mA/RS485/RS232/HART | Water level monitoring in reservoirs, lakes, and industrial tanks. | |
| ATO-LEVS-WSR550 | 10–60m | -40℃~80℃/-40℃~150℃ | 24V DC/220V AC | 4–20mA/RS485/HART | Process monitoring in steam, dust, and crystallization environments. | |
| ATO-LEVS-RD903 | 0–40m | -40℃~+130℃/-40~℃+230℃ | 12–24V DC/220V AC | 4–20mA/RS485/HART | Bulk material level monitoring for chunks, solids, and industrial raw materials. | |
|
Wireless |
ATO-LEVS-BRW100 | 0–10m | -10V~+60℃ | Battery-powered/9-30V DC | NB-IoT/4G/LoRa | Water conservancy and water supply water level monitoring. |
| ATO-LEVS-LM01 | 0–5m | -20°C~70°C | ≤100mA at 5V DC | 2.4G WiFi/Zigbee | Smart home and small industrial liquid storage tank monitoring. | |
| ATO-LEVS-212E | 3cm ~ 250cm | -40°C ~ +85°C | 9~36V DC | RS232/RS485/0-5V/BLE Bluetooth | Remote fuel and oil tank level monitoring in metal, plastic, or fiber tanks. |
Point-Level Sensors
| Level Switches |
Model SKU | Type | Working temperature | Power supply | Output signal | best for |
| ATO-MR-M12 | Optical Level Sensor | -20°C~+110°C | 5–24V DC | NPN / PNP | Low-level indicators to prevent run-dry conditions when using oil, coolant, or hydraulics. | |
| ATO-ELS-040 | Electrode level switch | -20°C~+200°C | 24V DC/220V AC | SPDT | Conductive liquid level detection, industrial liquid control. | |
| ATO-TFLS-501 | Tuning Fork Level Switch | -40°C~+80°C | 24V DC/220V AC | DPDT | Chemical tanks, power plants, and industrial liquid level switching. | |
| ATO-VLS-YN100 | Vibrating Rod Level Switch | -30°C~+200°C | 250V AC/30V DC/5A | SPDT | Powder, granule, and bulk solid level detection in silos and bins. | |
| ATO-PLS-004 | Rotary Paddle Level Switch | -20℃~+80℃ | 220V AC/110V AC/24V DC | SPDT | Monitor and control the level of bulk solids in bins, hoppers, and silos. |
Level sensors are widely used for industrial level measurement and process control, ensuring safe, efficient, and accurate monitoring of liquids and solids across tanks, silos, and open environments.
| Application | Media / Fluids | Recommended Level sensor | Advantages |
| Water Tank Monitoring | Clean water, municipal water, rainwater | Submersible/Capacitive Level Sensor | Low-cost and reliable continuous level measurement. |
| Industrial Water Storage | Process water, cooling water | Ultrasonic/Radar Level Sensor | Non-contact measurement ensures low maintenance. |
| Chemical Liquid Storage | Acids, alkalis, corrosive liquids | Radar Level Sensor | Safe and stable performance in harsh environments. |
| Pump Control Systems | Wastewater, raw water, effluents | Tuning Fork Level Switch | Simple ON/OFF control; reliable protection against dry-run and overflow. |
| Smart Water Monitoring | Remote tanks, reservoirs | Wireless Level Sensor | Low energy consumption; supports cloud-based remote monitoring. |
| Wastewater & Sludge Management | Sludge, dirty water, foam, solids | Radar/Submersible Level Sensor | Strong resistance to foam, turbulence, and suspended solids. |
| Open Channel & Reservoirs | River water, outdoor basins | Radar/Ultrasonic Level Sensor | Long-range non-contact measurement; stable performance in outdoor conditions. |
| Small Tanks & Compact Systems | Small chemical tanks equipment | Capacitive Level Sensor/Level Switch | Space-saving design; easy integration. |
| High-Temp / High-Pressure Systems | Hot fluids, pressurized vessels | Radar Level Sensor | Stable measurement under extreme temperature, pressure, and vapor conditions. |
Selecting the right ATO level sensor depends on medium type, measurement method, operating environment, and system compatibility.
Step 1: Identify the Level Measured Medium
The measured medium determines sensor compatibility.
Step 2: Determine Measurement Type
Decide whether continuous measurement or point-level detection is required.
Step 3: Select Contact or Non-Contact Technology
Installation conditions determine whether contact or non-contact sensing is required.
Step 4: Evaluate the Level Sensor Operating Environment
Step 5: Review Tank and Mounting Constraints
Before selecting the final sensor, consider the physical layout of your tank and installation requirements.
Q1: Radar vs Ultrasonic Level Sensor: Which One Should I Choose?
A: Use a radar level sensor for harsh environments and an ultrasonic level sensor for clean liquid applications.
Radar works best in vapor, foam, dust, high temperature, and pressure conditions, while ultrasonic is suitable for cost-effective water tank and reservoir monitoring.
Q2: Which ATO Level Sensor Is Best for Water Tanks?
A: Ultrasonic, submersible, and level switches are the best ATO sensors for water tanks.
Ultrasonic is used for non-contact measurement, submersible for deep tanks and wells, and level switches for overflow and pump control.
Q3: When should I use a submersible level sensor?
A: Use a submersible level sensor for deep tanks, wells, and underground liquid level measurement.
It is used in hydrostatic pressure-based applications where stable, continuous monitoring is required.
Q4: Which type of level switch is best for industrial use?
A: Tuning fork level switches are best for liquids, and vibrating rod level switches are best for powders and bulk solids.
They are used for reliable ON/OFF level detection in industrial control systems.
Q5: How do I choose between continuous and point-level sensors?
A: Choose continuous level sensors for real-time level measurement and point-level sensors for ON/OFF control.
Continuous sensors are used for process monitoring, while point-level sensors are used for alarms and pump protection.
Level sensors play a crucial role in modern industry and daily life, improving production efficiency, reducing costs, and ensuring safe operation.
Some level sensor applications can overlap, and when deciding on a sensor, it is important to identify the product that you are sensing and the type of feedback that your application requires. Sensors like tuning fork or optical level sensors can be used to indicate a high or low level. Ultrasonic and radar level sensors can measure your level to give specific feedback on how much product is in a tank. If you have any questions about purchasing, you can contact us.