Close
(0) Shopping cart
You have no items in your shopping cart.
Shopping Categories
    Filters
    Preferences
    Search

    1A 1 pole 6kA Miniature Circuit Breaker

    $33.38
    1 pole miniature circuit breaker with 1A current rating, and can safely be used in AC 50Hz or 60Hz, 230/400V with a 6 kA short circuit withstand rating, provide overload and short circuit protection for conductors.
    SKU: ATOCLXB1-01
    *
    *
    Delivery date: 6-12 days

    Circuit Breaker Information

    • Model: ATOCLXB1-01
    • Rated Current: 1amp
    • Rated Voltage: 230/400V AC, 50Hz/ 60Hz
    • Number of poles: 1 pole
    • 6 kA short circuit interrupting capacity
    • Accordance with IEC standard
    • Three different trip characteristics, including B, C and D curves, give you the ability to configure the exact protection scheme you required

    Technical Data

    Standard Certifications IEC UL1077
    Electrical Parameters Height 86 mm
    Width 18 mm per pole
    Mounting DIN Rail
    Rated Current (In) 1A, 2A, 3A, 4A, 6A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A (Available)
    Number of poles 1P, 2P, 3P, 4P (Available)
    Rated Voltage (Ue) (Optional) 240/415V or 230/400V 277/480V
    Rated Insulation Voltage (Ui) 500V
    Reted Frequency 50Hz/60Hz
    Short Circuit Interrupting Capacity (Optional) 6/10KA 5KA
    Trip Characteristic (Optional) B Curve (3-5In) B Curve (4In)
    C Curve (5-10In) C Curve (7In)
    D Curve (10-20In) D Curve (14In)
    Mechanical Parameters Electrical Life 8000 times
    Mechnical Life 10000 times
    Protection Degree IP20
    Calibration Temperature 30
    Operating Temperature -5℃~+40℃
    Storage Temperature -25℃~+70℃
    Tightening Torque 22 Ib-in (2 Nm)
    Terminal Size Acceptability–Min/Max 2.5 mm(12 AWG) / 25mm(3 AWG)

    Circuit Breaker Dimension

    circuit breaker dimensionTips: Circuit breaker working principle
    The main contacts of low voltage circuit breaker are operated manually or electrically. After the main contact is closed, it will be locked by the free tripping mechanism. The trip coil of over-current and the thermal element of thermal overload releaser are connected in series with the main circuit. The under-voltage releaser coil and the power supply are connected in parallel.

    1. When the circuit is short-circuited or severely over-loaded, the armature of over-current releaser will be pulled in to make the main contact cut off the main circuit under the effect of the free tripping mechanism.
    2. When the circuit is overloaded, the thermal elements of thermal releaser will bend the bimetal plates by heating to cut off the main circuit under the effect of the free tripping mechanism.
    3. When the circuit is in the state of under-voltage, the armature of under-voltage releaser will be released to cut off the main circuit under the effect of the free tripping mechanism.
    4. When the shunt trip is pressed, its armature will be pulled to cut off the main circuit under the effect of the free tripping mechanism.