    9 amp Mechanical Interlock AC Contactor

    $68.29
    SKU: ATO-ACCON-09N
    9 amp 3 pole or 4 pole mechanical interlocking AC contactor for sale at factory price, with coil rated voltage from 24V AC to 380V AC 50Hz or 60Hz, 3NO/4NO + auxiliary contact 2NC, has simple structure and easy mounting to control an electrical power circuit.

    12 amp Mechanical Interlock AC Contactor

    $69.79
    SKU: ATO-ACCON-12N
    12 amp 3 pole/ 4 pole mechanical interlocking AC contactor is an electrically controlled switch constructed with a mechanical interlock and two revering contactor, which is used for switching an electrical power circuit, coil rated voltage from 24V AC to 380V AC.

    400A DC Reversing Contactor, 2 pole, 12V/24V/48V

    $257.08
    SKU: ATO-DCCON-R400
    2 pole reversing contactor has been designed for direct current load, 2NO and 2NC ( DPST-NO, DPST-NC) contact form, rated load current is 400A. IP 50 protection, easy and quick installation, manufacturer direct sale.

    18 amp Mechanical Interlock AC Contactor

    $71.99
    SKU: ATO-ACCON-18N
    Low price 18 amp 3 pole/ 4 pole mechanical interlocking AC contactor with coil rated voltage from 24V AC to 380V AC is an electrically controlled switch constructed with a mechanical interlock and two revering contactor, which is used for controlling AC electric motors.

    50A DC Contactor, single pole, 12V/24V/48V

    $102.61
    SKU: ATO-DCCON-C50
    Single pole DC contactor with 12V, 24V, 48V coil voltage for choice, normally open type (SPST-NO), contact circuit rated load current of 50A, offers exceptional performance in an extremely small and lightweight device.

    25 amp Mechanical Interlock AC Contactor

    $87.99
    SKU: ATO-ACCON-25N
    3 pple/ 4 pole normally open mechanical interlocking AC contactor is a combination of two reversing contactor and a mechanical interlock, coil rated voltage from 24V AC, 36V, 48V to 380V, rated operational current 25 amp, which meets IEC standard.

    80A DC Contactor, single pole, 12V/24V/48V

    $114.36
    SKU: ATO-DCCON-C80
    80A rated current DC contactor has one normally open contact (SPST-NO), single pole, available any way to install, coil rated voltage with 12V/24V/48V DC for choice.

    100A DC Contactor, single pole, 12V/24V/48V

    $103.63
    SKU: ATO-DCCON-C100
    High performance 100A DC contactor with one normally open contact, and available with two optional auxiliary contacts. Coil rated voltage with 12V/24V/48V for selection, main contact voltage drop at 100A, not above 100mV.

    32 amp Mechanical Interlock AC Contactor

    $91.29
    SKU: ATO-ACCON-32N
    Factory price 3 pole/ 4 pole normally open mechanical interlocking AC contactor is a combination of two reversing contactor and a mechanical interlock, auxiliary contact 2NC, coil rated voltage from 24V AC, 36V, 48V to 380V, rated operational current 32 amp, which meets IEC standard.

    200A DC Contactor, single pole, 12V/24V/48V

    $121.65
    SKU: ATO-DCCON-C200
    This 200 amps contactor is available in coil voltage 12V, 24V, 48V, continuous operating duty, SPST-NO contact form, single pole DC contactor with high-performance quality, low cost and manufacturer direct sale.

    40 amp Mechanical Interlock AC Contactor

    $121.29
    SKU: ATO-ACCON-40N
    Normally open 3 pole/ 4 pole AC reversing contactor is an electrically controlled switch, which comes with a mechanical interlock to control electrical circuits and AC motors, selectable coil rated voltage of 24V, 36V, 48V, 110V, 220V, 380V AC, high performance and low price.

    50 amp Mechanical Interlock AC Contactor

    $124.29
    SKU: ATO-ACCON-50N
    50A 3 pole/ 4 pole normally open mechanical interlocking AC contactor is a combination of two reversing contactor and a mechanical interlock, which meets IEC standard, auxiliary contact 2NC, coil rated voltage from 24V AC, 36V, 48V to 380V.

    500A DC Contactor, single pole, 12V/24V/48V

    $205.63
    SKU: ATO-DCCON-C500
    500A high current contactor with single pole, designed for direct current loads, IP 50 protection, good quality and long life. They are available with two optional auxiliary contacts, 2A/48V DC or 5A/24V DC.

    600A DC Contactor, single pole, 12V/24V/48V

    $185.32
    SKU: ATO-DCCON-C600
    High current contactor, designed for DC loads, contact circuit rated load current is 600A, one normally open contact which has excellent conductivity. Single pole contactor, cheap price and manufacturer direct sale.

    65 amp Mechanical Interlock AC Contactor

    $125.89
    SKU: ATO-ACCON-65N
    AC reversing contactor with mechanical interlock for sale, coil rated voltage 24V, 36V AC to 380V AC, 65 amp 3 pole or 4 pole, auxiliary contact 2NC. This magnetic contactor drives the moving contact and the static contact to realize the purpose of connecting or breaking the circuit.

    80 amp Mechanical Interlock AC Contactor

    $142.59
    SKU: ATO-ACCON-80N
    Favorable price 80 amp 3 pole/ 4 pole mechanical interlocking AC contactor with coil rated voltage from 24V AC to 380V AC 50Hz or 60Hz, 3NO or 4NO + auxiliary contact 2NC, has simple structure and easy mounting to control an electrical power circuit.

    95 amp Mechanical Interlock AC Contactor

    $147.29
    SKU: ATO-ACCON-95N
    Reversing contactor with mechanical interlock sale online with economical price, coil rated voltage 24V, 36V AC to 380V AC, 3 pole or 4 pole, built-in auxiliary contacts 2 normally closed allows for extended logic control operations. This magnetic AC contactor has simple structure to control an electrical power circuit.

    115 amp 3 phase AC Magnetic Contactor, 24V/110V/220V coil

    $248.19
    SKU: ATO-ACCON-115A
    Buy 115 amp 3 pole AC magnetic contactor at factory price. 3 phase electrical contactor with coil voltage of 110V, 220V AC, 380V AC, auxiliary contact of 2NO+2NC, 4NO, 4NC, 1NO+1NC, 2NO, 2NC, rated insulation voltage 1000V, can frequently start and control AC electric motors.

    150 amp 3 phase AC Magnetic Contactor, 24V/110V/220V Coil

    $256.63
    SKU: ATO-ACCON-150A
    150 amp 3 pole AC magnetic contactor for sale at low price. 3 phase electrical contactor with coil voltage of 110V AC, 220V AC, 380V AC, auxiliary contact of normal close, normal open, rated insulation voltage 1000V, can frequently start and control AC electric motors.

    185 amp 3 phase AC Magnetic Contactor, 24V/110V/220V Coil

    $296.16
    SKU: ATO-ACCON-185A
    Low price 3 phase 3 pole AC magnetic contactor is used in electric motor control and DIN rail or panel mounting, with 110V/220V/380V coils. Different contact form are available, intended for frequently switching on and off 3 phase loads up to 185 amps.

    A contactor is an automatic electromagnetic switch that closes and disconnects the current through the contacts through electromagnetic force. In addition, the magnetic contactor also has a low pressure release function, which is suitable for frequent operation and running distance control.

    In electrical engineering, because the contactor is a device that can quickly cut off the AC and DC main circuits and can frequently turn on and off high-current control (up to 800A) circuits, it is often used in motors as control objects, and it can also be used as a control object. The electrical contactor is used to control electrical loads such as factory equipment, electric heaters, working mother machines and various power units. The contactor has a large control capacity, which is suitable for frequent operation and long-distance control, and is one of the important components in the automatic control system.

    Contactors are divided into AC contactors (voltage AC) and DC contactors (voltage DC). As a high-power switching device, it is widely used in aerospace, aviation, weapons, ships, electronics and other system equipment. The control load current is greater than 25A, and the voltage is 25VDC; 115VAC, 402Hz; 386VAC, 50Hz. The power distribution switch controls the power supply or controls the start-stop control of high-power motors. It is a key device in the equipment and plays an important role.

    How does the contactor work?

    The magnetic contactor is mainly composed of electromagnetic mechanism, contact system and arc extinguishing device. The electromagnetic mechanism is a sensing element, and when it senses a certain electrical signal, it will drive the contacts to close or break. It mainly includes coil, iron core and armature.

    When the contactor coil is energized, the coil current will generate a magnetic field, and the generated magnetic field will make the static iron core generate electromagnetic attraction to attract the moving iron core, and drive the AC contactor point to move, the normally closed contact is disconnected, the normally open contact is closed, and the two are linked. When the coil is powered off, the electromagnetic attraction disappears, and the armature is released under the action of the release spring, so that the contacts are restored, the normally open contacts are disconnected, and the normally closed contacts are closed. The working principle of a DC contactor is somewhat similar to that of a temperature switch.

    5 types of contactors on ATO.com

    DC contactor
    DC contactors

    DC contactor refers to a contactor whose iron core is DC control, and its load can be either DC or AC. The iron core of the DC contactor is different from the AC contactor. It has no eddy current, so it is generally made of mild steel or industrial pure iron into a round shape. Since the attracting coil of the DC contactor is connected to DC, there is no impact starting current, and there is no violent impact of the iron core, so it has a long service life and is suitable for frequent starting and stopping.

    AC contactor
    DC contactors

    AC contactors often use three types of arc extinguishing methods: double-break electric arc extinguishing, longitudinal seam arc extinguishing and grid arc extinguishing. It is used to eliminate the arc generated by the moving and static contacts during the opening and closing process. Contactors with a capacity of more than 10A have arc extinguishing devices. The AC contactor also has auxiliary components such as reaction spring, buffer spring, contact pressure spring, transmission mechanism, base and terminal.

    Vacuum contactor
    Vacuum contactor

    The vacuum contactor uses a vacuum interrupter to extinguish arcs to frequently connect and cut off the normal working current. It is usually used to remotely connect and disconnect medium and low voltage 6kV, 380V (660V, 1140V) with frequent start and stop. ) AC motor.

    Lighting contactor
    Lighting contactor.

    The lighting contactor is a relay switch, providing reliable and convenient lighting control. Magnetic contactors operate at lower but safer loads and optimize the electromagnetic system to reduce maintenance power.

    Definite purpose contactors
    Definite purpose contactor

    ATO has dedicated contactors designed for the heating, ventilation, air conditioning and refrigeration industries.

    What are the main parts of a contactor?

    Taking AC contactor as an example, it consists of electromagnetic mechanism, contact system, arc extinguishing system, reaction force device, bracket and base.

    1. Electromagnetic mechanism

    The composition of the electromagnetic mechanism: It is composed of electromagnetic coil, iron core and armature.

    The function of the electromagnetic mechanism: the closing and opening of the operating contacts.

    2. Contact system

    The magnetic contact is the first opening element of the contactor, which is used to make or break the controlled circuit. The contact system includes main contacts and auxiliary contacts.

    • Main contact: Used in the main circuit with large on-off current.
    • Auxiliary contact: Used to connect or disconnect the control circuit, only a small current can be passed.

    3. Arc extinguishing system

    Contactors with a capacity of more than 10A have arc extinguishing devices, often using longitudinal slit arc extinguishing covers and grid arc extinguishing devices.

    4. Reaction device

    Including spring, transmission mechanism, terminal and shell, etc.

    5. Brackets and bases

    For fixing and installation of contactors.

    Difference between AC contactor and DC contactor

    1. The main difference between AC contactor and DC contactor is in the iron core and coil. There are eddy currents in the electromagnet core of the AC contactor, so the electromagnet cores are made into pieces and stacked together. The electromagnet core of the current contactor is an integral iron core, the coil is slender and the number of turns is particularly large.

    2. The main circuit of the DC contactor is generally two poles, and the DC only has positive and negative poles. The AC contactor has three poles because of the opening and closing of three-phase electricity.

    3. For the AC circuit, when the contactor is disconnected, the overvoltage generated by the circuit is small. At the same time, when the AC arc has a zero-crossing time, the arc will be extinguished and reignited after the zero-crossing, so the AC arc measures are relatively easy. For the DC circuit, when the contactor is disconnected, the overvoltage generated by the circuit is too high, and the arc is not easy to extinguish. It can be seen that compared with the AC contactor, the DC arc extinguishing measures are relatively difficult.

    4. The protection coordination relationship (SCPD) of DC and AC is different, and the parameter table must be carefully consulted when using.

    Why use contactors to control motors?

    When the motor starts, its starting current is very large. Generally, the starting current of the motor should be 5-7 times, and the starting current of the small-capacity motor is larger. When the motor is disconnected, since the motor is an inductive load, a relatively high voltage will be induced at both ends of the switch contacts at the moment of disconnection, thereby breaking down the air gap between the contacts and forming an arc. Therefore, the electrical appliance that controls the breaking motor must have the ability to withstand the impact of the starting current and extinguish the arc when it is disconnected. Therefore, an electrical appliance with the above-mentioned capabilities, such as a contactor or an air switch, is chosen to control the breaking motor.

    The control relay node does not have the above functions, so use the relay node to start the contactor, and use the contactor node to control the motor. In places with a high degree of automation, the contactor is used as the final actuator for the start and stop of the motor due to its low price and reliability. Large motors above 4200KW are also controlled by air switches. This is often used in large industrial enterprises, because at this capacity class, the contactor is not sufficient. The most important thing is that the contactor can meet the closing-opening operation of 300,000 times, and can meet the component life requirements of frequent starting and stopping electrical circuits.