Close
(0) Shopping cart
You have no items in your shopping cart.
Shopping Categories
    Filters
    Preferences
    Search

    Check Valves

    View as Grid List
    Display per page
    Sort by

    2-1/2" Dual Plate Wafer Check Valve

    $78.82
    SKU: ATO-DPCV-65
    High quality 2-1/2 inch dual plate check valve is a wafer type non-return valve with ductile iron materials, DN65 and PN 1.6MPa, which can prevent backflow in a wide range of fluid handling applications.

    3" Dual Plate Wafer Check Valve

    $97.51
    SKU: ATO-DPCV-80
    Good price 3" dual plate check valve, wafer type, ductile iron, PN 1.6MPa, and DN80. It responds quickly and reliably to changes in flow direction, suitable for applications where reverse flow is frequent.

    3/4 inch Brass Swing Check Valve

    $46.35
    SKU: ATO-BSCV-DN20
    3/4 inch (DN20) horizontal check valves with a threaded connection can be used on lines supplying auxiliary systems where the pressure may rise above the primary system pressure. Brass non-return valve, swing type, low price, suitable for applications where backflow prevention is required.

    8" Plastic Foot Valve, FRPP Non Return Valve

    $650.88
    SKU: ATO-PFV-200
    The provided 8 inch plastic foot valve is equipped with a flange connection, DN200 and 10kg PN. A corrosion-resistant FRPP non-return valve is ideal for handling chemicals and corrosive fluids.

    1 inch Brass Swing Check Valve

    $47.67
    SKU: ATO-BSCV-DN25
    Buy 1 inch (DN25) swing check valves online to regulate and control the flow of fluids through pipes. Brass horizontal check valve, working pressure 1.6Mpa, used in water supply systems, heating systems and pipeline systems.

    4" Dual Plate Wafer Check Valve

    $129.75
    SKU: ATO-DPCV-100
    Good price 4" dual plate check valve, wafer type, available in ductile iron materials, PN 1.6MPa, and DN100. This wafer non return valve responds quickly and reliably to changes in flow direction, suitable for applications where reverse flow is frequent.

    1-1/4 inch Brass Swing Check Valve

    $51.78
    SKU: ATO-BSCV-DN32
    Buy a 1-1/4" (DN32) check valve directly from a check valve supplier. It is a swing non-return valve with a 1.6Mpa working pressure and thread connection. Durable brass check valve is widely used in various pipeline projects such as water plants, papermaking, heating, refrigeration, petroleum, construction, etc.

    5" Dual Plate Wafer Check Valve

    $157.64
    SKU: ATO-DPCV-125
    Factory price 5 inch (DN125) dual plate check valve for sale online. It is a wafer non return valve that can prevent liquid and gas backflow, ductile iron materials, PN 1.6MPa, ideal for oil and gas, chemical processing, water treatment and power stations.

    1-1/2 inch Brass Swing Check Valve

    $54.52
    SKU: ATO-BSCV-DN40
    Low price 1-1/2 inch (DN40) brass swing check valve comes with 1.6Mpa working pressure and thread connection. Horizontal check valve, reliable and low maintenance, used for the piping system to prevent backflow of water.

    6" Dual Plate Wafer Check Valve

    $195.66
    SKU: ATO-DPCV-150
    Hot selling 6" (DN150) wafer check valve is designed for regulating the flow of fluid through pipelines. Dual plate check valve is commonly used in water and wastewater treatment, oil and gas pipelines, and industrial processing.

    2 inch Brass Swing Check Valve

    $63.63
    SKU: ATO-BSCV-DN50
    Order 2 inch (DN50) check valve directly from a check valve supplier. It is a swing-type NRV valve with a 1.6Mpa working pressure and thread connection. Relaible brass non-return valve is widely used in various pipeline projects such as water plants, papermaking, heating, refrigeration, petroleum, construction, etc.

    8" Dual Plate Wafer Check Valve

    $292.64
    SKU: ATO-DPCV-200
    8 inch (DN200) dual plate wafer check valve for sale online. Wafer type, clip connection, PN 1.6MPa. Low cost non return valve is widely used in water and wastewater treatment plants to prevent polluted water backflow.

    A check valve, also known as a non-return valve or one way valve, is a mechanical device that allows fluid or gas to flow in one direction only and prevents backflow in the opposite direction. NRV valve is designed to automatically open and close in response to the pressure or flow of the fluid or gas, without requiring external control or power. ATO 1 inch, 2 inch, 4 inch to 12 inch check valves are commonly used in piping systems, water pumps, compressors, and other fluid handling equipment to prevent reverse flow, backpressure, and water hammer. 

    4 Types of Check Valves

    • Swing check valve: Swing type check valve has a disc or flap that swings open when the fluid flows in the correct direction and closes when the fluid flows back in the opposite direction.
    • Ball check valve: This ball-type check valve uses a ball that sits on a seat to allow flow in one direction and prevent flow in the opposite direction.
    • Wafer check valve: The wafer non-return valve is installed between two flanges and uses a disc that moves up and down to allow flow in one direction and prevent backflow.
    • Foot valve: A foot valve for water pump is used to prevent backflow and maintain the prime in a pump suction line. It is typically installed at the bottom of a suction pipe or wellbore.

    Types of check valve

    Materials of Non-Return Valves

    • Stainless steel: This is a popular material for check valves due to its corrosion resistance, durability, and strength.
    • Brass: Brass is commonly used for non-return valves in plumbing applications due to its corrosion resistance, ductility, and machinability.
    • PVC: PVC check valves are used in applications where chemical resistance is required, such as in water treatment and chemical processing. UPVC and CPVC are both thermoplastic materials that are derived from PVC through chemical modifications.
    • Cast iron: Cast iron non-return valves are used in applications where strength and durability are required, such as in industrial and municipal applications.

    How to Choose the Right NRV Valve?

    Choosing the right check valve for your application can be critical to ensure the efficient and reliable operation of your system. Here are some key factors to consider when selecting a check valve:

    • Application: Consider the type of fluid, flow rate, pressure, and temperature of the system. The check valve should be able to handle these conditions without causing excessive pressure drop, cavitation, or erosion.
    • Type of check valve: Select the appropriate type of nrv valve based on the flow direction, installation orientation, and system requirements. For example, a swing check valve is suitable for horizontal installations, while a lift check valve is better suited for vertical installations.
    • Material: Choose the material of the check valve based on the properties of the fluid being transported, environmental conditions, and compatibility with other materials in the system. Consider factors such as corrosion resistance, chemical compatibility, and durability.
    • Size: Select the appropriate size of the check valve based on the pipe diameter and flow rate of the system. 1", 1/2"..2".. 4" to 12" check valves are available on ATO.com.
    • End connections: Choose the appropriate end connections of the nrv valve based on the type of piping system and the connection method (flanged, threaded, or welded).
    • Maintenance and repair: Consider the ease of maintenance and repair of the check valve, including accessibility, availability of spare parts, and repair services.

    What is a Non-Return Valve Used for?

    1/2" to 12" non-return valve is used to allow the flow of fluids or gases in one direction only while preventing backflow in the opposite direction. Non-return valves are commonly used in piping systems to prevent damage to equipment, contamination of fluids or gases, and safety hazards. They are used in a wide range of applications, including:

    • Pump discharge lines: Non-return valves are often used in pump discharge lines to prevent the backflow of fluid into the pump when it is turned off or when the system pressure drops below the pump discharge pressure.
    • Steam systems: Non-return valves are commonly used in steam systems to prevent the backflow of condensate into the steam lines. This can help to prevent damage to steam equipment and ensure the efficient operation of the system.
    • Water supply lines: Non-return valves are used in water supply lines to prevent the backflow of contaminated water into the clean water supply. This is especially important in industrial and municipal water systems.
    • HVAC systems: Non-return valves are commonly used in heating, ventilation, and air conditioning (HVAC) systems to prevent the backflow of air or water into the system. This can help to ensure the proper operation of the system and prevent damage to HVAC equipment.
    • Chemical processing: Non-return valves are often used in chemical processing applications to prevent the backflow of hazardous chemicals into the system. This can help to ensure worker safety and prevent environmental contamination.