Measure coil resistance, resistance of a power relay coil can be measured with the R×10Ω band, thus judging whether the coil has open circuit. Measure actuation voltage and actuation current, with an adjustable stabilized voltage supply and ammeter, the power relay can be input with a voltage while the ammeter can be connected in series to monitor. Slowly increase the power supply. Voltage and record the actuation voltage and actuation current when the power relay is attracted. For accuracy, more operations can be repeated to get the average value. Measure release voltage and release current, connect wires as the test above. When the power relay is attracted, reduce the power supply voltage slowly and record the voltage and current as hearing the relay to release again. More operations can be repeated to get the average value.